Dubai — Showroom
The Pinnacle Building, Sheikh Zayed Road, Office 607
Mon–Fri: 9:00 – 18:00
The gasket is the shortest-lived part of an aluminium window in this country, and it fails quietly. Ultraviolet and a summer design temperature of 46°C, with peaks above 50°C, harden the EPDM, airborne sand grinds at it through every shamal, and one day the sash still shuts but the room is dustier and louder than it used to be. Replacement runs around the whole contour rather than the length that looks worst, in the gasket profile the system was designed around — not a universal strip cut to fit. We do this on the windows we made and installed.
Hard and cracked
Condition
Rubber ages before the profile
South and west first
Elevation
Sun does most of the damage
System-specific
Gasket profile
Groove shape decides it
Whole contour
Scope
Part-lengths leak at the joint
Our own systems
Coverage
Other brands: windowrepair.ae
Get a free calculation for your windows — just leave your number, we'll reply on WhatsApp within 15 minutes.
Three contours of EPDM seals keep the glass off the aluminium and close the gap between sash and frame, so dust, humid salt air and wind-driven rain stay outside.
Learn more
Foamed inserts fill the profile chambers and stop air circulating inside them, so less outside heat and street noise passes through the frame into the cooled room.
Learn more
Glass-filled polyamide thermal breaks up to 40 mm wide keep the outer and inner shells apart, so the frame holds its shape and its insulation through a UAE summer.
Learn more
Double glazing up to 60 mm thick puts a sealed gap of still air or gas between the hot street and the cooled room, so less heat crosses the glass into the room.
Learn moreThe honest downside
A gasket can only seal a sash that closes true. A dropped sash can be adjusted at the same visit; a twisted frame or an opened corner joint cannot, and a new gasket then meets the frame unevenly, so the draught, dust and noise come back along the gap it cannot reach.
Seals also have nothing to do with fog between the panes, which is a failed glass unit, or with water entering around the outside of the frame on a tower, which is usually a facade joint. New rubber in the sash leaves both exactly as they were.
Where damp shows around a window on an upper floor, the joints outside are the likelier cause, and tracing and resealing them from ropes is the repair that stops it. Seal replacement is the right job when a sound frame lets in air, dust or noise along the sash edge.
Consider instead
Joint sealing at height
Nearby pages and the rest of the catalogue.
Sections
Company
The Pinnacle Building, Sheikh Zayed Road, Office 607
Mon–Fri: 9:00 – 18:00
Profiles, glass units and hardware to see and touch before you choose.
Free measurement
Leave your number — we call back to agree a time that suits you.
We reply within 15 minutes during working hours.