Smoke vents

A smoke vent is an opening that stays shut for years and has to work on the single day it is called. It is not an optional extra: where the fire strategy for a building requires smoke to be let out of a stairwell, an atrium or a car park, the vent is part of the approved design and is signed off alongside the other life-safety systems. Our part is the aluminium unit, its actuators and its control line — built to the consultant's drawing and proved in front of the people who accept it.

  • roof or facade position
  • motorised actuation
  • backed-up power supply
Request a quote

Why choose aluminium windows?

  • Aluminium window profile cross-section with three EPDM seal contours highlighted in red

    Durable EPDM seals

    Three contours of EPDM seals keep the glass off the aluminium and close the gap between sash and frame, so dust, humid salt air and wind-driven rain stay outside.

    Learn more
  • Aluminium window profile cross-section with a foamed thermal insert highlighted

    Foamed thermal inserts

    Foamed inserts fill the profile chambers and stop air circulating inside them, so less outside heat and street noise passes through the frame into the cooled room.

    Learn more
  • Aluminium window profile cross-section with polyamide thermal breaks highlighted

    Polyamide thermal breaks

    Glass-filled polyamide thermal breaks up to 40 mm wide keep the outer and inner shells apart, so the frame holds its shape and its insulation through a UAE summer.

    Learn more
  • Aluminium window profile with an energy-efficient double glazing unit highlighted

    Energy-efficient double glazing

    Double glazing up to 60 mm thick puts a sealed gap of still air or gas between the hot street and the cooled room, so less heat crosses the glass into the room.

    Learn more

What a smoke vent is made of

  • Roof or facade

    Position

    Fixed by the smoke strategy

  • Chain or spindle

    Actuator

    Sized to swing the leaf fully open

  • Dedicated panel

    Control

    Takes its signal from the alarm

  • Backed-up supply

    Power

    Still opens with the mains down

  • Weather sealed

    Everyday duty

    Shut tight against heat and sand

Modern villa with panoramic aluminium glazing and a pool at sunset

Let's calculate
the cost of glazing

Get a free calculation for your windows — just leave your number, we'll reply on WhatsApp within 15 minutes.

How a smoke vent package is delivered

  • Requirement read off the approved fire strategy We build to the drawing, never to a guess
  • Positions coordinated on the real structure Roof framing and facade openings checked
  • Actuators and controls specified Opening force matched to the leaf weight
  • Interface with the alarm agreed Contractor and consultant in one meeting
  • Assembled and cycled in our Dubai factory Each unit run before it leaves the bench
  • Installed, commissioned and witness tested Opened in front of the parties who sign

Articles

The honest downside

When a smoke vent is not what you need

A smoke vent is a life-safety device first. Its position, size and control are fixed by the building's approved fire strategy, it needs a dedicated panel and a backed-up supply, and it has to be tested and serviced for as long as the building stands — whether or not it is ever called on.

That makes it a poor choice for a job that is really about comfort. If what you want is to let the hot air out of the top of a villa stairwell, a smoke vent brings all of that obligation for a task a simpler opening can do.

Where no fire strategy calls for one, an opening skylight on a motor with a rain sensor vents the stairwell and lets in daylight as well. A smoke vent is the answer wherever the approved design requires it — and then it is not optional.

Consider instead Skylights

Frequently asked questions

The fire strategy for the building does — prepared by the appointed fire consultant and approved by the authority before construction. Positions, opening areas, opening angles and the way the vents respond to the alarm all come from that document. We manufacture, install and commission to it, and we take part in the witnessed test; what we never do is invent the requirement or offer to reduce it.

The control panel runs from a backed-up supply, so the vents still travel when the mains has gone. That is not a claim to be taken on trust: it is demonstrated at commissioning with the supply isolated, and it is worth checking again at every maintenance visit, because a battery that has quietly aged is a typical fault on an older installation.

You do not, unless it is tested. Heat, ultraviolet light and grit are what age the seals, the hinges and the actuator here, and they do it whether the unit is used or not. Periodic testing belongs to owning one: the units are cycled, the tracks cleaned, the panel and the batteries checked and any parts that have gone stiff replaced — a routine that can be agreed at handover.

Some units can be specified to do both, and on a stairwell that is genuinely useful. The condition is that the fire function always wins: an alarm signal overrides whatever anyone has pressed, and the unit returns to its safety position. That dual behaviour has to be agreed with the fire consultant and written into the design before anything is built.

Partitions

Office partitions made of aluminium profiles are a simple, quick, and cost-effective way to organise efficient zoning within a large space, while maintaining interior unity.

We are always happy to welcome you at our showroom

Main Office

Dubai — Showroom

The Pinnacle Building, Sheikh Zayed Road, Office 607

Mon–Fri: 9:00 – 18:00

+971 50 220 6913

Showroom

Samples to see in person

Profiles, glass units and hardware to see and touch before you choose.

Dubai — Showroom The Pinnacle Building, Sheikh Zayed Road, Office 607
Get directions